We are proud of large number of delivery results |
High temp. and High pressure Air heater |
Heater for air heating
can be manufactured, designed, and sold as the heat source of the test facility that the high temp. and high pressure is required. |
For the combustion testing of the small airplane engine |
Model SHW-2000 |
|
|
This was delivered to JAXA as the air heater for the Heater capacity 3-phase 420V 2000kW Max. use hot-air temp. 1000K (727゚C) Resisting pressure 5MPa Max. usable air volume 186Nm3/min |
|
Heat source for chemical fiber production devices |
Model 6BL4-110-0.4MPa |
|
Heater capacity 3-phase 200V 110kW Max. use hot-air temp. 400゚C (Suction temp. 220゚C) Resisting pressure 0.35MPa Max. usable air volume 10 - 50Nm3/min |
|
|
For the combustion testing of the high temp. and high pressure internal combustion engine |
Model SHW-480 |
|
Heater capacity 3-phase 400V 480kW Max. use hot-air temp. 850゚C Resisting pressure 0.49MPa Max. usable air volume 20Nm3/min Characteristic Change function of the heater output Hot-start function (Preheat operation) |
|
|
High pressure block heater (For drying the catalytic) |
|
|
Heater capacity 3-phase 440V 30kW Max. use hot-air temp. 80゚C Resisting pressure 0.88MPa Max. usable air volume 12Nm3/min Characteristic With Auto-temp. controller TCU-20K The second pressure vessel structure standard official approval pass article |
|
|
High temp. and high pressure heater for generating the hot-air |
Model XS-3B-3MPa |
|
|
Heater capacity 3-phase 200V 5kW Max. use hot-air temp. 350゚C Resisting pressure 3MPa Max. usable air volume 0.5Nm3/min Characteristic With the sensor for managing the outlet temp. With the overheat prevention sensor |
|
Model Super heater Multiple type |
|
|
Max.
use hot-air temp.
500゚C |
|
Model Pen heater Multiple type |
|
|
Max.
use hot-air temp.
750゚C |
|
High temp. air heater |
Consecutive RAM combustion air heater |
Air heater for
combustion test of super low Nox |
Air heater for
|
Model SHW-130 | Model SHW-600 | Model SHW-730 | Model SHW-850 |
Heater
capacity : 130kW Max. use hot-air temp. : 1000゚C Resisting pressure : 0.49MPa |
Heater capacity : 600kW Max. use hot-air temp. : 1000゚C Resisting pressure : 0.97MPa |
Heater
capacity : 730kW Max. use hot-air temp. : 727゚C Resisting pressure : 4.89MPa |
Heater
capacity : 850kW Max. use hot-air temp. : 850゚C Resisting pressure : 0.97MPa |
|
||
SHW-730 | SHW-2000 and trial attendant body | SHW-800 |
|
|
|
Super heater multiple use | Super heater multiple use | |
|
Kansai Electric Heat Corp. |
4-18, Takaidanishi 5-chome, Higashiosaka-city 577-8566 JAPAN |
TEL : +816-6785-6001 FAX : +816-6785-6002 |